58 research outputs found

    The preliminary investigation of imaging photoplethysmographic system

    Get PDF
    A preliminary CCD camera-based imaging photoplethysmographic (PPG) system is described to detect the blood perfusion in tissue. Attention of imaging photoplethysmography (PPG) is drawn to the potential applications in visualised blood perfusion. The introduction of the fast digital camera inspires the development of imaging PPG which allows the ideally contactless monitoring with larger field of view and different depth of tissue by applying multi-wavelength LEDs. The CCD camera-based spectral imaging PPG system in both transmission mode and reflection mode is constructed to validate the feasibility of this technique. The PPG signal can be derived in both transmission mode and reflection mode, which is obviously different from multi-wavelength LEDs or monitoring at various regions of tissue. The investigation for the system functionality leads to the further development of imaging PPG system and the engineering model for 3-D visualised blood perfusion of tissue

    Opto-physiological modeling applied to photoplethysmographic cardiovascular assessment

    Get PDF
    This paper presents opto-physiological (OP) modeling and its application in cardiovascular assessment techniques based on photoplethysmography (PPG). Existing contact point measurement techniques, i.e., pulse oximetry probes, are compared with the next generation noncontact and imaging implementations, i.e., non-contact reflection and camera-based PPG. The further development of effective physiological monitoring techniques relies on novel approaches to OP modeling that can better inform the design and development of sensing hardware and applicable signal processing procedures. With the help of finite-element optical simulation, fundamental research into OP modeling of photoplethysmography is being exploited towards the development of engineering solutions for practical biomedical systems. This paper reviews a body of research comprising two OP models that have led to significant progress in the design of transmission mode pulse oximetry probes, and approaches to 3D blood perfusion mapping for the interpretation of cardiovascular performance

    Feasibility of imaging photoplethysmography

    Get PDF
    Contact and spot measurement have limited the application of photoplethysmography (PPG), thus an imaging PPG system comprising a digital CMOS camera and three wavelength light-emitting diodes (LEDs) is developed to detect the blood perfusion in tissue. With the means of the imaging PPG system, the ideally contactless monitoring with larger field of view and the different depth of tissue by applying multi- wavelength illumination can be achieved to understand the blood perfusion change. Corresponding to the individual wavelength LED illumination, the PPG signals can be derived in the both transmission and reflection modes, respectively. The outcome explicitly reveals the imaging PPG is able to detect blood perfusion in a illuminated tissue and indicates the vascular distribution and the blood cell response to individual wavelength LED. The functionality investigation leads to the engineering model for 3-D visualized blood perfusion of tissue and the development of imaging PPG tomography

    Feasibility of Imaging Photoplethysmography

    Get PDF
    Contact and spot measurement have limited the application of photoplethysmography (PPG), thus an imaging PPG system comprising a digital CMOS camera and three wavelength light-emitting diodes (LEDs) is developed to detect the blood perfusion in tissue. With the means of the imaging PPG system, the ideally contactless monitoring with larger field of view and the different depth of tissue by applying multi- wavelength illumination can be achieved to understand the blood perfusion change. Corresponding to the individual wavelength LED illumination, the PPG signals can be derived in the both transmission and reflection modes, respectively. The outcome explicitly reveals the imaging PPG is able to detect blood perfusion in a illuminated tissue and indicates the vascular distribution and the blood cell response to individual wavelength LED. The functionality investigation leads to the engineering model for 3-D visualized blood perfusion of tissue and the development of imaging PPG tomography

    BioThreads: a novel VLIW-based chip multiprocessor for accelerating biomedical image processing applications

    Get PDF
    We discuss BioThreads, a novel, configurable, extensible system-on-chip multiprocessor and its use in accelerating biomedical signal processing applications such as imaging photoplethysmography (IPPG). BioThreads is derived from the LE1 open-source VLIW chip multiprocessor and efficiently handles instruction, data and thread-level parallelism. In addition, it supports a novel mechanism for the dynamic creation, and allocation of software threads to uncommitted processor cores by implementing key POSIX Threads primitives directly in hardware, as custom instructions. In this study, the BioThreads core is used to accelerate the calculation of the oxygen saturation map of living tissue in an experimental setup consisting of a high speed image acquisition system, connected to an FPGA board and to a host system. Results demonstrate near-linear acceleration of the core kernels of the target blood perfusion assessment with increasing number of hardware threads. The BioThreads processor was implemented on both standard-cell and FPGA technologies; in the first case and for an issue width of two, full real-time performance is achieved with 4 cores whereas on a mid-range Xilinx Virtex6 device this is achieved with 10 dual-issue cores. An 8-core LE1 VLIW FPGA prototype of the system achieved 240 times faster execution time than the scalar Microblaze processor demonstrating the scalability of the proposed solution to a state-of-the-art FPGA vendor provided soft CPU core

    A remote approach to measure blood perfusion from the human face

    Get PDF
    A CMOS camera-based imaging photoplethysmography (PPG) system has been previously demonstrated for the contactless measurement of skin blood perfusion over a wide tissue area. An improved system with a more sensitive CCD camera and a multi-wavelength RCLED ring light source was developed to measure blood perfusion from the human face. The signals acquired by the PPG imaging system were compared to signals captured concurrently from a conventional PPG finger probe. Experimental results from eight subjects demonstrate that the camera-based PPG imaging technique is able to measure pulse rate and blood perfusion

    Development of a remote photoplethysmographic technique for human biometrics

    Get PDF
    Non-contact reflection photoplethysmography (NRPPG) is being developed to trace pulse features for comparison with contact photoplethysmography (CPPG). Simultaneous recordings of CPPG and NRPPG signals from 22 healthy subjects were studied. The power spectrum of PPG signals were analysed and compared between NRPPG and CPPG. The recurrence plot (RP) was used as a graphical tool to visualize the time dependent behaviour of the dynamics of the pulse signals. The agreement between NRPPG and CPPG for physiological monitoring, i.e. HRV parameters, was determined by means of the Bland-Altman plot and Pearson’s correlation coefficient. The results indicated that NRPPG could be used for the assessment of cardio-physiological signals

    Remote simultaneous dual wavelength imaging photoplethysmography: a further step towards 3-D mapping of skin blood microcirculation

    Get PDF
    This paper presents a camera-based imaging photoplethysmographic (PPG) system in the remote detection of PPG signals, which can contribute to construct a 3-D blood pulsation mapping for the assessment of skin blood microcirculation at various vascular depths. Spot measurement and contact sensor have been currently addressed as the primary limitations in the utilization of conventional PPG system. The introduction of the fast digital camera inspires the development of the imaging PPG system to allow ideally non-contact monitoring from a larger field of view and different tissue depths by applying multi-wavelength illumination sources. In the present research, the imaging PPG system has the capability of capturing the PPG waveform at dual wavelengths simultaneously: 660 and 880nm. A selected region of tissue is remotely illuminated by a ring illumination source (RIS) with dual-wavelength resonant cavity light emitting diodes (RCLEDs), and the backscattered photons are captured by a 10-bit CMOS camera at a speed of 21 frames/second for each wavelength. The waveforms from the imaging system exhibit comparable functionality characters with those from the conventional contact PPG sensor in both time domain and frequency domain. The mean amplitude of PPG pulsatile component is extracted from the PPG waveforms for the mapping of blood pulsation in a 3-D format. These results strongly demonstrate the capability of the imaging PPG system in displaying the waveform and the potential in 3-D mapping of blood microcirculation by a non-contact means

    Detection of physiological changes after exercise via a remote optophysiological imaging system

    Get PDF
    A study of blood perfusion mapping was performed with a remote opto-physiological imaging (OPI) system coupling a sensitive CMOS camera and a custom-built resonant cavity light emitting diode (RCLED) ringlight. The setup is suitable for the remote assessment of blood perfusion in tissue over a wide range of anatomical locations. The purpose of this study is to evaluate the reliability and stability of the OPI system when measuring a cardiovascular variable of clinical interest, in this case, heart rate. To this end, the non-contact and contact photoplethysmographic (PPG) signals obtained from the OPI system and conventional PPG sensor were recorded simultaneously from each of 12 subjects before and after 5-min of cycling exercise. The time-frequency representation (TFR) method was used to visualize the timedependent behavior of the signal frequency. The physiological parameters derived from the images captured by the OPI system exhibit comparable functional characteristics to those taken from conventional contact PPG pulse waveform measurements in both the time and frequency domains. Finally and more importantly, a previously developed optophysiological model was employed to provide a 3-D representation of blood perfusion in human tissue which could provide a new insight into clinical assessment and diagnosis of circulatory pathology in various tissue segments

    Real-time VLSI architecture for bio-medical monitoring

    Get PDF
    This paper discusses the architecture and implementation of SSS2, a high-performance real-time signal processing system developed with a hybrid ESL/RTL methodology and targeted to biomedical image processing. Traditional methodologies, as well as new tools, such as Cebatech's C2R untimed-C synthesizer have been employed in the design of the system. The SSS2 platform specifies a parametric number of scalar processing elements, based on multiple 32-bit Sparc-compliant engines, augmented with LE2, an ESL-designed 2-way LIW/SIMD accelerator. LE2, which is purely designed in C, exposes a consistent interface to its SIMD datapath directly which is directly derived from the C-source of open-source image processing codes. It is synthesized to Verilog RTL with C2R. Behaviorally-synthesized SIMD datapaths are then 'plugged-in' into the exposed LE2 datapath interface. The LE2 memory interface can be either a cache- based configurable vector load/store unit or a multi-banked, multi-channel streaming local memory system. Results drawn from this work strongly suggest a shift towards a hybrid approach in designing multi-core systems for high bandwidth streaming and for dealing with large scale medical image transfers and non-linear bio-signal processing algorithms
    • …
    corecore